Rabu, 27 Agustus 2014

Fan coil Roll

To re-rolled coil fan that has been damaged or burned is actually not too difficult, provided that already know how,
             First of course we prepare the tools needed to roll back the fan coil stretcher namely:
1 Micro meter, in order to measure the diameter of the wire spool, fan usually used for household size 0,15mm.atau 0,18mm
2 Multitester, to check if there are broken wires.
3 Wire Spool 0,15mm
4. Prespan Mika 0.12 and 0.15, for isolation.
5. Hand sakle thread Electrik wind machine, to roll up the wire.
6 As well as other equipment that is needed, such as keys.


First remove the broken wire from the fan tran damaged as shown above, cut into pieces using a pliers, if isolatornya damaged replace with a new one, as shown below



After completion of all insulation / installation prespan mica, we measure the width and circumference of the fan tran like this, in order to make the size, or large wire ring that will roll:

Furthermore, we make the mold wire size according to the length and width that was created earlier in the plywood that has been provided in accordance with the size of that size have been obtained earlier, as below:
Further



Next we started to roll, starting from zero at the thread anggka machine, winding up to 900, and made ​​as much as 4x, without interruption, as shown below, because the average fan coil that much use.


Furthermore, we make rolls for round 1,2,3 again, its because the average fan has 3 speeds, first we make a roll of 500 rounds made ​​4x as much as the first one, made ​​a barrier with a stick that has been provided so that no join between reels 1 and 2, then the rolls or rolled overwritten again by using two wires at the same time, these rolls 200 rolls, so the total length of the roll is the same with the last roll of the first coil 900 (500 + 200 + 200) (500 coil wire marked wear isolation so that when these connections are not wrong) As the picture below:
  Rolls below the second and third rolls using two wires at once let gulungnya quickly.
Now we start entering the first wire (double wire 3) into the fan tran like this:
Position the wire with the tracks / picture below, not to reverse. if inverted fan will not spin.

For the second installation of the wire coils / rolls starting, insert between the end of the first wire was / rolls running. as shown below.
Now we connect the ends of the wire, the wire ends before we burn a little to open the email or wire wrapping,
Here's how to make the connections:
Double wire 3 we love names a, b, c, aja (a = 200 coils, coil b = 200, c = 500 coils) and a single wire that we love the name x (900 coils), so easy to dial,
Double coil 3 would have as many as 6 tip end, namely a, a1, b, b1, c and c1 and the first end of the coil 2 x and x1.
X combined with the tip end of a1, b1 tip combined with a, b combined with the tip end of c1, so now the tip of the wire into as many as 5 tip. As below:

The tip is used for incoming fire x1 x tip that has been merged with the tip speed becomes no.1 a1, b1 tip which has been combined with a, be a speed no.2, b1 tip which has been combined with the speed c became no.3,
To end c is used for the capacitor, the capacitor mounting end and ends x1 c. For incoming fire safety thermostat should be installed 1amp.
After completion of spliced ​​and soldered the ends wrapped with shells that have been provided as below:
Further
  Furthermore scrolls tied as below:
After finishing tied scrolls given a varnish to help reduce the heat, and also helps to keep the rolls do not shake, as below.
Now we wait to dry and then we put as before.
Good luck.
Best of luck.

Tidak ada komentar:

Posting Komentar

Related Posts Plugin for WordPress, Blogger...